D739 - Protected Floor Assembly Design (Cellular Deck) |
|
MK-6, RG, Z-106, Z-146 |
D743 - Protected Floor Assembly Design (Min. 2" Concrete) |
|
MK-6, RG, Z-106, Z-146 |
D744 - Protected Floor Assembly Design (Unclassified Paint) |
|
MK-6, RG, Z-106, Z-146 |
D779 - Protected Floor Assembly Design (Fluted Deck) |
|
MK-6, RG, Z-106, Z-146, Z-156 |
D780 - Protected Floor Assembly Design (Corrugated Deck) |
|
MK-6, RG, Z-106, Z-146 |
D782 - Protected Floor Assembly Design (Min. 3-1/4" LW Concrete) |
|
MK-6, RG, Z-106, Z-146, Z-156 |
D925 - Unprotected Floor Assembly Design |
|
MK-6, RG, Z-106, Z-146, Z-156 |
J709 - Poured LW Concrete Slab Design |
|
MK-6, RG, Z-106 |
J712 - Poured NW Concrete Slab Design |
|
MK-6, RG, Z-106, Z-146, Z-156 |
J957 - Precast Concrete Slab Design |
|
MK-6, RG, Z-106 |
N706 - Beam Only Design for Floor Assemblies |
|
MK-6, RG |
N708 - Beam Only Design for Floor Assemblies |
|
MK-6, RG |
N777 - Joist Only Design for Floor Assemblies |
|
MK-6, RG, Z-106, Z-146, Z-156 |
N779 - Beam Only Design for Floor Assemblies |
|
MK-6, RG, Z-106, Z-146, Z-156 |
N782 - Beam Only Design for Floor Assemblies |
|
MK-6, RG, Z-106, Z-146, Z-156 |
N789 - Joist Only Design for Floor Assemblies |
|
MK-6, Z-106, Z-146 |
P714 - Protected Roof Assembly Design (Polystyrene Board) |
|
MK-6, RG |
P725 - Protected Roof Assembly Design (Polystyrene Over GWB) |
|
MK-6, RG, Z-106, Z-146, Z-156 |
P732 - Protected Roof Assembly Design (Polyiso Board) |
|
MK-6, RG, Z-106, Z-146 |
P733 - Protected Roof Assembly Design (Sprayed Foam) |
|
MK-6, Z-106, Z-146, Z-156 |
P936 - Unprotected Roof Assembly Design (Insulating Concrete) |
|
MK-6, RG, Z-106, Z-146 |
S728 - Joist Only Design for Roof Assemblies |
|
MK-6, RG, Z-106, Z-146 |
S734 - Beam Only Design for Roof Assemblies |
|
MK-6, RG, Z-106, Z-146, Z-156 |
S735 - Beam Only Design for Roof Assemblies |
|
MK-6, RG, Z-106, Z-146, Z-156 |
S736 - Joist Only Design for Roof Assemblies |
|
MK-6, RG, Z-106, Z-146 |
WRG/CF 194-01 - Tube Steel Beams |
|
MK-6 |
X795 - W-shaped, Round or Tube Steel Column Design |
|
Z-146, Z-156 |
XR711 - Hydrocarbon Steel Column Design (Contour Shape) |
|
Z-146, Z-156 |
XR715 - Hydrocarbon Steel Column Design (Box Shape) |
|
Z-146, Z-156 |
XR718 - Hydrocarbon Steel Column Design (Contour Shape) |
|
Z-146, Z-156 |
Y710 - Round or Tube Steel Column Design |
|
MK-6, RG, Z-106 |
Y715 - W-shaped Steel Column Design |
|
MK-6, RG |
Y724 - W-shaped Steel Column Design |
|
Z-106 |
|